Introduction

Current radiological literature is strongly focussed on radiation imaging risks [1]; it may be worthwhile to assess the safety of alternative imaging modalities used in the paediatric population. Since it is a small but actual augment in cancer risk from exposure to ionizing radiation in children, it is important to understand what the risks of alternative techniques could be.

Therefore, the aim of this article was to make a risk/benefit analysis of avoiding the use of X-rays in favour of other imaging modalities, focusing our attention on MR imaging (MRI). To achieve this goal, we investigated the recent literature and reviewed our experience to optimize the MR approach in children.

Methods

We performed a PubMed research (“Magnetic Resonance Imaging”[Mesh] AND “safety”[Mesh]), obtaining 817 results. Adding the filter “Child: birth -18 years”, the papers were reduced to 125. Search results for ((“gadolinium”[MeSH Terms] OR “gadolinium”[All Fields]) AND deposition [All Fields] AND (“brain”[MeSH Terms] OR “brain”[All Fields])) were 142 papers.

Lastly, searching for (“Magnetic Resonance Imaging”[Mesh] AND “safety”[Mesh] AND “sedation”) we obtained 22 papers. If integrated with (“safety”[MeSH Terms] OR “safety”[All Fields]) AND (“pediatrics”[MeSH Terms] OR “pediatrics”[All Fields] OR “pediatric”[All Fields]) AND “MRI”[All Fields], found papers were 564.

Among those papers, we focussed on articles specifically addressed to risks of MRI safety on paediatric population, about biological effects, gadolinium-related and sedation risks at the end we selected 73 articles and statements considered more relevant according to author’s agreement that are discussed in this paper.

Risks related to MRI medical examinations in the paediatric population

MRI related risks can be summarized in: biological effects of non-ionizing electromagnetic fields (EMF) employed; risks from noises produced during MRI examinations; hazards from ferromagnetic external and/or implanted devices; risks associated with sedation or general anaesthesia or related to gadolinium-based contrast agents (GBCA) [2].

Biological effects of non-ionizing electromagnetic fields employed in MRI

The three sources of EMF used in MRI are the following: static magnetic fields (SMF), gradient fields (GMF), and radiofrequency (RF). The mechanisms of interaction with human tissues are polarization, induced current, and thermal heating, respectively. FDA has approved exposure of adults to 7 T fields and exposure of neonates to 4 T fields.

Usually, Institutional Review Boards (IRBs) define MRI as a minimal risk technique so it is approved for numerous research protocols, including in children [3]. Minimal risk means “the probability (of occurrence) and magnitude (seriousness) of harm or discomfort (e.g. psychological, social, legal, economic) associated with the research are not greater than those ordinarily encountered in daily life (of the average person in the general population) or during the performance of routine physical or psychological examinations or tests.” [4].

MRI is considered the safe alternative to CT, but paradoxically, one of the most alarming issues concerning MRI regards the possible “genotoxic” effects [5].

Hartwig [6] demonstrated that EMF generated during MRI diagnostic scans have genotoxic effects, in terms of micronuclei (MN) induction (carcinogenesis). Anyway, the genetic damage should be reversible: after 48 h, the MN number returned to that of the controls, suggesting that two cell divisions are enough to eliminate them. In conclusion, the authors suggested prudent use to avoid superfluous examinations, according to the precautionary principle. However, the precautionary principle is positive only if the restraint of a procedure has less damaging side effects than benefits of usage [7]. Simi [8] reported a dose-dependent (1.5 T scanner, with a maximum gradients strength of 50 mT m−1, and a maximum gradients speed of 150 mT m−1 s−1) increase of MN frequency in vitro that returned to control values after 24 h when the exposure was within diagnostic levels. In vivo, a significant increase in MN was found till 24 h and after the frequencies slowly returned to control values. [9].

The issue of biological damage and DNA repair capacity is also the key point of the studies on detrimental effect of X-ray radiation [10]. Kuefner [11] stressed that individual factors, including radiation sensitivity and DNA repair capacity, determine the DNA damage level. There may be similar assumptions for MR, but according to Leszczynski, even if single EMF exposures cause only negligible fully reversible effects, i.e. slightly changed phosphorylation of proteins, multiple EMF tests might increase the risk that one of these changes might lead to an irreversible effect [12]. The dilemma is: in children’s growing organs mitoses are more frequent, but cancer incidence significantly increases in the elderly [13]. The apparent contradiction is likely to be justified in the greater potential of chromosome damage repair in children. Besides, in everyday life, we are subjected to a series of environmental insults that cannot be genotoxic “in themselves”, but may increase the negative effects of other biological, chemical and/or physical agents [8]. In a study by Magin [14] on (sub) chronicle exposures, no statistically significant changes were observed in foetal growth in animals (mice) exposed to only MR or ultrasound fields. Conversely, in the combined ultrasound and MR exposed group, foetal weight and crown-rump length were reduced compared to the controls. Luckily, analysis of cognitive and biometric data from a decade-long longitudinal fMR study of normal language development in a small, longitudinal sample of healthy children who received up to 10 MR scans provided evidence of minimal (if any) risk [3]. Salerno et al. demonstrated the effect on human lymphocyte activation cytokine release by SMF in 0.5 T MR [15, 16].

The most common/known biological problem during MR is that of heating, due to RF fields [17]. This heating of tissues is maximum at the surface and minimal at the centre of the body. A rise of 1 °C is generally acceptable for a normal healthy body. Usually, there are no problems in adults, who dissipate heat mainly with peripheral vasodilatation. Infants and newborns, particularly if preterm, have immature thermoregulation [17, 18]. The RF power absorbed per unit of mass of an object is defined Specific Absorption Rate (SAR) and is measured in watts per kilogram (W kg−1). SAR rises with the square of the static MF. To avoid overheating of any local area, the limits of the product of time and local SAR (W min kg−1) are defined by international guidelines. For exposures of infants, a reduction of these values by a factor of two is recommended [18, 19]. For children in general and infants/newborns, the time factor is crucial. Many technical issues cause an increase of examination time, such as smaller coils to maximize local signal (enclosing a larger portion of the body, and augmenting RF heating in turn), respiratory triggering and cardiac gating, and controlled ventilation [20].

During sedation/anaesthesia, which limits intrinsic thermoregulation, body temperature is the result of a sum of factors: the cool environment, hypothermia because of passive heat loss (large surface area-to-body weight ratio), heating due to RF fields [21]. According to Isaacson, hypothermia (− 1 °C or more) is possible in young patients propofol-sedated [22]. Conversely, a case of iatrogenic hyperthermia occurring in a 16-month-old infant during anaesthesia for cardiac MR (fentanyl, rocuronium, sevoflurane) was reported [23]. The patient was scanned with a head coil for 19 consecutive series over 95 min with a 1.5 T magnet. The pulse sequences included fast spin echo sequences, which are associated with the highest SARs. At the end of the examination, the heart rate was 200 bpm and axillary temperature was 38 °C. Other series of infants propofol-sedated do not confirm hypothermia, reporting a prevalence of heating: probably, the depth of sedation may influence the degree of thermoregulatory impairment [24]. In summary, local temperature fluctuations are difficult to predict.

Risks related to noises produced during MR examinations

Various types of acoustic noise are produced during MRI. The primary source of noise is the GMF with flexing and vibration of the gradient coils [25]. The noise is manifested as loud tapping, knocking, or chirping sounds. Neonates with undeveloped anatomical structures may have an amplified reaction to acoustic noise, i.e. important changes in vital signs of newborns have been described during MR examinations, which may be due to acoustic noise. This could augment the chance of hearing loss and could have an adverse effect on neurosensory and physiologic short-term and long-term natural growth and development of the neonate [26]. Noise levels differ with diverse MR sequences and are directly related to static field strength [25]. MHRA states [27]: the use of earplugs, ear defenders, or other hearing protections is highly recommended. Groups of concerns are paediatric and neonate patients, and the foetus. It is recommended that staff and others remaining in the scan room (i.e. parents) wear non-metallic earplugs and/or ear defenders. In the case of the anaesthetized patients, hearing protection should always be provided. Another source of acoustic noise is the so-called RF hearing (click, buzz, chirp, or knocking noise) [25].

Time-varying magnetic fields also induce electric fields in patients, stimulating nerves or muscles. At sufficient amplitudes, peripheral nerve stimulation is perceptible (i.e. tingling or tapping sensations). Safety standards avoid cardiac stimulation [28].

Risks from ferromagnetic external objects and implanted devices

The risk of ferromagnetic projectiles unintentionally carried inside the scanning room of an MR setting is greater in children (especially in the newborns and infants) than in adults. If a young child needs MR, the clinical problem is usually severe and almost always sedation or anaesthesia is necessary. Usually, they have supplementary equipment, such as monitoring, ventilation and infusion pumps. As synthesized by Arthur [17]: proper requirements must be accessible when sick young children are in the MR environment: MR-compatible fibre-optic temperature monitoring, pulse oximeter, ECG leads. Standard equipments such as laryngoscope blades, handles and stethoscopes are usually not MR compatible. All emergency care is best performed outside the immediate scanner environment (outside the 5-Gauss line) to minimize the risk of ferromagnetic projectile.

Concerning implanted devices, these are special in children and must be known (Fig. 1). They can determine electromagnetic field interactions, MR-related heating, and the creation of artefacts. As well as longer-term central venous catheters, implanted programmable cerebrospinal fluid (CSF) shunts (to be resected after imaging), implanted cardiac devices and cochlear implants are typical of paediatric patients. The FDA’s Centre for Devices and Radiological Health (CDRH) proposes terms to be used to label MR information for medical devices [29]:

Fig. 1
figure 1

CT angiography sagittal reconstruction of a 1-year-old female with congenital heart disease with Berlin Heart, a paediatric mechanical ventricular assist device (arrow); in these cases, magnetic resonance (MR) imaging is contraindicated

  • MR Safe: an item that poses no known hazards in all MR environments;

  • MR Conditional: an item that has been demonstrated to pose no known hazards in a specified MR environment with specified conditions of use;

  • MR Unsafe: an item that is known to pose hazards in all MR environments.

Owing to the complexity of the conditions faced and the heterogeneity of the implanted devices, in our Hospital we identified a flow chart that has the justification of the examination as starting point and subsequently advises that the physician retrieves the information on the device from the manufacturer, identifying the degree of MR safety. The increasing amount of data on all specific devices will ultimately allow to build a database, enabling real-time decisions.

Risks associated with sedation and anaesthesia

The most common cause of artefacts on MR images is patient motion. In children, the mix of patient collaboration, fast/irregular respiratory frequency, and tiny anatomy can make the exam extremely challenging. In MR performed in paediatric patients, spatial resolution is crucial, but unfortunately there is an inverse relationship between spatial resolution and signal-to-noise ratio (SNR), which is proportional to the square root of the acquisition time [30].

NICE guidelines suggest [31]: “for children and young people […] during diagnostic imaging consider either chloral hydrate for children under 15 kg, or midazolam. If these are not suitable, consider one of the following drugs ministered by a specialist healthcare professional with a narrow margin of safety: propofol, sevoflurane”. Long scan times evidently make sedation/anaesthetic indispensable in paediatric MR [32]. The principal short-term risks are under-sedation or over-sedation. Under-sedation is inadequate reduction of movements to obtain diagnostic images. In younger children, over-sedation increases the risk of desaturation or apnoea. Furthermore, adverse events, especially pulmonary complications, also include patients with obesity, history of snoring, and developmental disabilities. In children with congenital cardiac diseases, the frequency of adverse events was estimated to be between 0 and 10.4% [33] and direct patient observation is prevented by physical separation. Besides, little is known about the long-term effects after exposure to analgesics or sedatives [34]. Practices for the induction of general anaesthesia, as masks or cannulas, can also create panic in the child [32]. Alternative techniques such as oral sucrose solution, “feed and wrap” or “feed and sleep” practices can be valid solutions. According to Edwards [32], “feed and wrap” is ideal for children younger than 1 year, oral or intravenous sedation between 1 and 5 years, and distraction therapies for > 6 year olds. Usually, the necessity of “urgent” examinations favours anaesthesia (i.e. baseline oncology imaging that implies prolonged examination times). There is a need to balance the choice between the risk of failing the exam, the use of alternative techniques such as CT (considering any diagnostic limits), and performing anaesthesia directly (if the organization allows it) [35].

In any case, intensive use of techniques to reduce artefacts, such as respiratory gating (or triggering), respiratory compensation (or phase re-ordering), navigator echoes, ECG gating, contributing to long acquisition times, is required in children.

Risks associated with gadolinium-based contrast agents (GBCA)

GBCAs can increase the accuracy of MR examinations, but many risks associated with the administration of exogenous contrast media must be taken into account [36]. All GBCAS are administered to humans in the form of chelates to avoid the presence of free gadolinium (Gd3+), which is toxic. The molecular structure can be linear or macrocyclic, and ionic or non-ionic. In linear GBCAs, the ion of Gd is surrounded by an open structure. Macrocyclic agents have a complete ring encasing the ion of Gd in a structure which tends to hold it more firmly, thus being more resistant to its release [37]. The association between GBCA exposure and the development of Nephrogenic Systemic Fibrosis (NSF) is widely accepted [38]. In healthy individuals, the half-life of GBCAs is usually 1.5 h, while in severely impaired renal function patients the half-life is increased up to approximately 30 h [39]. Only 23 paediatric NSF cases have been described and all patients were 6 years of age or older. Seventeen of these children had documented exposure to GBCAs [40].

The association of brain MR abnormalities (Abnormal T1 Shortening in Deep Brain Areas) with a history of linear GBCA administration was firstly reported by Kanda [41]. Increased signal intensity in the dentate nucleus and globus pallidus on unenhanced T1-weighted images (T1WI) showed a positive correlation with previous exposure to GBCAs with an apparent dose–response relationship (Fig. 2a, b). Macrocyclic GBCAs seem to be less linked to this phenomenon [42,43,44,45,46,47]. The same phenomenon has been also reported in children [48,49,50,51,52,53]. The studies have been focused in three directions: (1) detection of increased T1-weighted signal intensity (SI) or R1 relaxation rate in deep grey matter structures; (2) direct detection of Gd and measurement of Gd concentration in human tissues (brain, other organs) [45] [54,55,56,57]; (3) animal studies (detection and measurement of Gd levels, imaging investigations, Gd deposit speciation) [58,59,60]. To date, no histological changes in brain tissues after repeated GBCA administration have been found. Clinical significance of gadolinium deposition and potential long-term consequences in the brain remain unclear. For all these reasons, EMA’s Committee for Medical Products for Human Use (CHMP) has recently published several precautions and recommendation on the use of GBCAs for MR [61].

Fig. 2
figure 2

a, b Pre-contrast T1-weighted images of a 13-year-old girl affected by suprasellar germinoma treated with chemotherapy and radio-therapy. a First MRI at the onset (11 years). A clear dentate nucleus hyperintensity (arrows) is visible after 6th from previous MR (b); only a macrocyclic GBCA was used

ESUR Contrast Medium Safety Committee recommends avoiding unnecessary exposure of children to GBCAs, especially in neonates and infants. Contrast agents with highest risk of NSF (linear) are contraindicated in neonates and should be used with caution in children aged less than 1 year [62]. However, Bedoya [63] investigated the effect of intravenous contrast material (linear) on renal function in a large population of neonates and concluded that, in the absence of known renal failure, neonates receiving standard patient care do not appear to be at increased risk for developing renal toxicity due to the administration of intravenous iodine- or gadolinium-based contrast media.

Paediatric acute allergic-like reactions to GBCA are rare: 0.04–0.08% per dose vs. 0.18% for iodinated contrast agents [5, 64,65,66].

Conclusions

The main role of imaging is to help patients by influencing clinical management, simultaneously reducing imaging-related risks without negative consequences on efficacy as much as possible. MR is paramount in the evaluation of the brain, musculoskeletal system, and spine. As for the abdomen, MR is multi-parametric and has an incomparable contrast resolution, excellent for oncology. In detail, it can create a variety of tissues contrasts that can even be co-registered, increasing lesion conspicuity [30, 67].

Unfortunately, MR is also somewhat operator dependent in its execution and, to be effective, time consuming. Conversely, CT is faster, cheaper, and much easier to perform. As Arthurs stated [5]: a well-performed CT will yield better diagnostic information than a poorly performed MR. The duration of MR means sedation or anaesthesia and risks of over-sedation, causing respiratory depression. The major events requiring resuscitation occur in 1% of patients, depending on the exact drug regimen used and staff experience [35]. Paradoxically, in this context the main risk in imaging concerns MR. The drawback of CT is the risk of ionizing radiation. Syndrome associated with paediatric tumours, such as Beckwith–Wiedemann syndrome and, even more, DNA repair diseases (Fanconi anaemia, ataxia-telangectasia, etc.), which are characterized by immunodeficiency and/or predisposition to cancer development, need a screening by imaging [68,69,70]. Despite the presumed genotoxicity, MR is considered the technique of choice in this case: many cancer-prone diseases have been shown to be radiosensitive due to pitfalls in the mechanisms of repair of induced DNA lesions.

Up to date there is not yet an adequate consensus about the MR-related cancer risks and the World Health Organization affirmed that “the carcinogenicity of static magnetic fields to humans is not at present classifiable”. But a study conducted by Ray et Al must be mentioned, since it demonstrated that there is not actual carcinogenetic risk, when performing MR in foetal period—first trimester [70, 71].

Whole‐body MR (WB-MR) is an increasingly used technique in paediatric oncology (Sequences that are typically employed in WB-MR include short tau inversion recovery (STIR), usually obtained using respiratory compensation techniques, and diffusion-weighted whole-body imaging with background body signal suppression (DWIBS), which are free breathing sequences [72]. The limits of WB-MR are poor sensitivity (motion artefacts, partial volume planes) and poor specificity (pitfalls due to growth variants) [73]. Besides, technological advancements in CT (reduced radiation doses in sub-second scan times) improve the potentials of CT and we should re-evaluate its use in at-risk paediatric patients. Diagnostic images are produced without breath-holds and patient cooperation and, thus, without general anaesthesia. A typical example is Cardiac CT [33].

In summary, particularly in young children, the choice between CT and MR should be decided on a case-by-case basis, considering efficacy first and avoiding radio-phobic attitudes. Of course, the costs, the urgency, and the availability of machines also play a primary role.