Skip to main content

Advertisement

Log in

Optical coherence tomography in dermatology: technical and clinical aspects

  • Review Article
  • Published:
Archives of Dermatological Research Aims and scope Submit manuscript

Abstract

Optical coherence tomography (OCT), a fairly new non-invasive optical real-time imaging modality, is an emergent in vivo technique, based on the interference (Michelson interferometry) of infrared radiation and living tissues, that allows high-resolution, 2- or 3-dimensional, cross-sectional visualisation of microstructural morphology of tissues. OCT provides depth-resolved images of tissues with resolution up to a few micrometers and depth up to several millimetres depending on tissue type. The investigations using OCT to assess skin structure in clinical settings started in the past decade and consequently proved that this imaging method is useful in visualizing subsurface structures of normal skin, including the epidermis, dermoepidermal junction, dermis, hair follicles, blood vessels and sweat ducts. An increasing number of papers brought evidence of the utility and the precision of OCT technology, in its different technical variants, in diagnosing and monitoring skin disorders, including malignancies and inflammatory conditions, respectively. The present comprehensive review describes and illustrates technical aspects and clinical applications of OCT methods in dermatology.

This is a preview of subscription content, log in via an institution to check access.

Access this article

Price excludes VAT (USA)
Tax calculation will be finalised during checkout.

Instant access to the full article PDF.

Institutional subscriptions

Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
Fig. 6
Fig. 7
Fig. 8
Fig. 9
Fig. 10
Fig. 11
Fig. 12
Fig. 13
Fig. 14
Fig. 15

Similar content being viewed by others

References

  1. Aalders MC, Triesscheijn M, Ruevekamp M, de Bruin M, Baas P, Faber DJ, Stewart FA (2006) Doppler optical coherence tomography to monitor the effect of photodynamic therapy on tissue morphology and perfusion. J Biomed Opt 11(4):044011. doi:10.1117/1.2337302

    Article  PubMed  Google Scholar 

  2. Abuzahra F, Spoler F, Forst M, Brans R, Erdmann S, Merk HF, Obrigkeit DH (2010) Pilot study: optical coherence tomography as a non-invasive diagnostic perspective for real time visualisation of onychomycosis. Mycoses 53(4):334–339. doi:10.1111/j.1439-0507.2009.01717.x

    PubMed  Google Scholar 

  3. Alex A, Povazay B, Hofer B, Popov S, Glittenberg C, Binder S, Drexler W (2010) Multispectral in vivo three-dimensional optical coherence tomography of human skin. J Biomed Opt 15(2):026025. doi:10.1117/1.3400665

    Article  PubMed  Google Scholar 

  4. Altintas MA, Altintas AA, Guggenheim M, Niederbichler AD, Knobloch K, Vogt PM (2009) In vivo evaluation of histomorphological alterations in first-degree burn injuries by means of confocal-laser-scanning microscopy-more than “virtual histology?”. J Burn Care Res 30(2):315–320. doi:10.1097/BCR.0b013e318198e746

    Article  PubMed  Google Scholar 

  5. Altintas MA, Altintas AA, Guggenheim M, Steiert AE, Aust MC, Niederbichler AD, Herold C, Vogt PM (2010) Insight in human skin microcirculation using in vivo reflectance-mode confocal laser scanning microscopy. J Digit Imaging 23(4):475–481. doi:10.1007/s10278-009-9219-3

    Article  PubMed  Google Scholar 

  6. Barton JK, Gossage KW, Xu W, Ranger-Moore JR, Saboda K, Brooks CA, Duckett LD, Salasche SJ, Warneke JA, Alberts DS (2003) Investigating sun-damaged skin and actinic keratosis with optical coherence tomography: a pilot study. Technol Cancer Res Treat 2(6):525–535

    PubMed  CAS  Google Scholar 

  7. Bechara FG, Gambichler T, Stucker M, Orlikov A, Rotterdam S, Altmeyer P, Hoffmann K (2004) Histomorphologic correlation with routine histology and optical coherence tomography. Skin Res Technol 10(3):169–173. doi:10.1111/j.1600-0846.2004.00038.x

    Article  PubMed  CAS  Google Scholar 

  8. Buder K, Knuschke P, Wozel G (2010) Evaluation of methylprednisolone aceponate, tacrolimus and combination thereof in the psoriasis plaque test using sum score, 20-MHz-ultrasonography and optical coherence tomography. Int J Clin Pharmacol Ther 48(12):814–820

    PubMed  CAS  Google Scholar 

  9. Cahill RA, Mortensen NJ (2010) Intraoperative augmented reality for laparoscopic colorectal surgery by intraoperative near-infrared fluorescence imaging and optical coherence tomography. Minerva Chir 65(4):451–462

    PubMed  CAS  Google Scholar 

  10. Chen Z, Milner TE, Srinivas S, Wang X, Malekafzali A, van Gemert MJ, Nelson JS (1997) Noninvasive imaging of in vivo blood flow velocity using optical Doppler tomography. Opt Lett 22(14):1119–1121

    Article  PubMed  CAS  Google Scholar 

  11. Choi B, Milner TE, Kim J, Goodman JN, Vargas G, Aguilar G, Nelson JS (2004) Use of optical coherence tomography to monitor biological tissue freezing during cryosurgery. J Biomed Opt 9(2):282–286. doi:10.1117/1.1648647

    Article  PubMed  Google Scholar 

  12. Choma M, Sarunic M, Yang C, Izatt J (2003) Sensitivity advantage of swept source and Fourier domain optical coherence tomography. Opt Express 11(18):2183–2189

    Article  PubMed  Google Scholar 

  13. Chu CR, Izzo NJ, Irrgang JJ, Ferretti M, Studer RK (2007) Clinical diagnosis of potentially treatable early articular cartilage degeneration using optical coherence tomography. J Biomed Opt 12(5):051703. doi:10.1117/1.2789674

    Article  PubMed  CAS  Google Scholar 

  14. Cimalla P, Walther J, Mehner M, Cuevas M, Koch E (2009) Simultaneous dual-band optical coherence tomography in the spectral domain for high resolution in vivo imaging. Opt Express 17(22):19486–19500. doi:10.1364/OE.17.019486

    Article  PubMed  CAS  Google Scholar 

  15. de Boer JF, Cense B, Park BH, Pierce MC, Tearney GJ, Bouma BE (2003) Improved signal-to-noise ratio in spectral-domain compared with time-domain optical coherence tomography. Opt Lett 28(21):2067–2069

    Article  PubMed  Google Scholar 

  16. de Giorgi V, Stante M, Massi D, Mavilia L, Cappugi P, Carli P (2005) Possible histopathologic correlates of dermoscopic features in pigmented melanocytic lesions identified by means of optical coherence tomography. Exp Dermatol 14(1):56–59. doi:10.1111/j.0906-6705.2005.00229.x

    Article  PubMed  Google Scholar 

  17. Drexler W (2004) Ultrahigh-resolution optical coherence tomography. J Biomed Opt 9(1):47–74. doi:10.1117/1.1629679

    Article  PubMed  Google Scholar 

  18. Drexler W, Andersen PE (2009) Optical coherence tomography in biophotonics. J Biophotonics 2(6–7):339–341. doi:10.1002/jbio.200910542

    Article  PubMed  Google Scholar 

  19. Faber DJ, Mik EG, Aalders MC, van Leeuwen TG (2005) Toward assessment of blood oxygen saturation by spectroscopic optical coherence tomography. Opt Lett 30(9):1015–1017

    Article  PubMed  CAS  Google Scholar 

  20. Fan C, Wang Y, Wang RK (2007) Spectral domain polarization sensitive optical coherence tomography achieved by single camera detection. Opt Express 15(13):7950–7961

    Article  PubMed  Google Scholar 

  21. Fercher AF (1993) Ophthalmic interferometry. In: von Bally G, Khanna S (eds) Optics in medicine, biology and environmental research. Selected contributions to the First International Conference on Optics Within Life Sciences (OLWS I), Garmisch-Partenkirchen, Germany, 12–16 August 1990 (ICO-15 SAT). Elsevier, Amsterdam, pp 221–228

    Google Scholar 

  22. Fercher AF (2008) Inverse scattering, dispersion and speckle in optical coherence tomography. In: Drexler W, Fujimoto JG (eds) Optical coherence tomography, pp 119–146

  23. Fercher AF, Roth E (1986) Ophthalmic laser interferometry. In: Proceedings of the SPIE—The International Society for Optical Engineering, vol 658, pp 48–51

  24. Fercher AF, Hitzenberger CK, Drexler W, Kamp G, Sattmann H (1993) In vivo optical coherence tomography. Am J Ophthalmol 116(1):113–114

    PubMed  CAS  Google Scholar 

  25. Fercher AF, Mengedoht K, Werner W (1988) Eye-length measurement by interferometry with partially coherent light. Opt Lett 13(3):186–188

    Article  PubMed  CAS  Google Scholar 

  26. Forsea AM, Carstea EM, Ghervase L, Giurcaneanu C, Pavelescu G (2010) Clinical application of optical coherence tomography for the imaging of non-melanocytic cutaneous tumors: a pilot multi-modal study. J Med Life 3(4):381–389

    PubMed  Google Scholar 

  27. Fruhstorfer H, Abel U, Garthe CD, Knuttel A (2000) Thickness of the stratum corneum of the volar fingertips. Clin Anat 13(6):429–433. doi:10.1002/1098-2353(2000)13:6<429

    Article  PubMed  CAS  Google Scholar 

  28. Fujimoto JG (2003) Optical coherence tomography for ultrahigh resolution in vivo imaging. Nat Biotechnol 21(11):1361–1367. doi:10.1038/nbt892

    Article  PubMed  CAS  Google Scholar 

  29. Gambichler T, Boms S, Stucker M, Kreuter A, Moussa G, Sand M, Altmeyer P, Hoffmann K (2006) Epidermal thickness assessed by optical coherence tomography and routine histology: preliminary results of method comparison. J Eur Acad Dermatol Venereol 20(7):791–795. doi:10.1111/j.1468-3083.2006.01629.x

    PubMed  CAS  Google Scholar 

  30. Gambichler T, Boms S, Stucker M, Kreuter A, Sand M, Moussa G, Altmeyer P, Hoffmann K (2005) Comparison of histometric data obtained by optical coherence tomography and routine histology. J Biomed Opt 10(4):44008. doi:10.1117/1.2039086

    Article  PubMed  Google Scholar 

  31. Gambichler T, Boms S, Stucker M, Moussa G, Kreuter A, Sand M, Sand D, Altmeyer P, Hoffmann K (2005) Acute skin alterations following ultraviolet radiation investigated by optical coherence tomography and histology. Arch Dermatol Res 297(5):218–225. doi:10.1007/s00403-005-0604-6

    Article  PubMed  Google Scholar 

  32. Gambichler T, Huyn J, Tomi NS, Moussa G, Moll C, Sommer A, Altmeyer P, Hoffmann K (2006) A comparative pilot study on ultraviolet-induced skin changes assessed by noninvasive imaging techniques in vivo. Photochem Photobiol 82(4):1103–1107. doi:10.1562/2005-12-21-RA-757

    Article  PubMed  CAS  Google Scholar 

  33. Gambichler T, Hyun J, Moussa G, Tomi NS, Boms S, Altmeyer P, Hoffmann K, Kreuter A (2007) Optical coherence tomography of cutaneous lupus erythematosus correlates with histopathology. Lupus 16(1):35–38

    Article  PubMed  CAS  Google Scholar 

  34. Gambichler T, Kunzlberger B, Paech V, Kreuter A, Boms S, Bader A, Moussa G, Sand M, Altmeyer P, Hoffmann K (2005) UVA1 and UVB irradiated skin investigated by optical coherence tomography in vivo: a preliminary study. Clin Exp Dermatol 30(1):79–82. doi:10.1111/j.1365-2230.2004.01690.x

    Article  PubMed  CAS  Google Scholar 

  35. Gambichler T, Matip R, Moussa G, Altmeyer P, Hoffmann K (2006) In vivo data of epidermal thickness evaluated by optical coherence tomography: effects of age, gender, skin type, and anatomic site. J Dermatol Sci 44(3):145–152. doi:10.1016/j.jdermsci.2006.09.008

    Article  PubMed  Google Scholar 

  36. Gambichler T, Moussa G, Bahrenberg K, Vogt M, Ermert H, Weyhe D, Altmeyer P, Hoffmann K (2007) Preoperative ultrasonic assessment of thin melanocytic skin lesions using a 100-MHz ultrasound transducer: a comparative study. Dermatol Surg 33(7):818–824. doi:10.1111/j.1524-4725.2007.33175.x

    Article  PubMed  CAS  Google Scholar 

  37. Gambichler T, Moussa G, Regeniter P, Kasseck C, Hofmann MR, Bechara FG, Sand M, Altmeyer P, Hoffmann K (2007) Validation of optical coherence tomography in vivo using cryostat histology. Phys Med Biol 52(5):N75–N85. doi:10.1088/0031-9155/52/5/N01

    Article  PubMed  CAS  Google Scholar 

  38. Gambichler T, Moussa G, Sand M, Sand D, Orlikov A, Altmeyer P, Hoffmann K (2005) Correlation between clinical scoring of allergic patch test reactions and optical coherence tomography. J Biomed Opt 10(6):064030. doi:10.1117/1.2141933

    Article  PubMed  Google Scholar 

  39. Gambichler T, Orlikov A, Vasa R, Moussa G, Hoffmann K, Stucker M, Altmeyer P, Bechara FG (2007) In vivo optical coherence tomography of basal cell carcinoma. J Dermatol Sci 45(3):167–173. doi:10.1016/j.jdermsci.2006.11.012

    Article  PubMed  Google Scholar 

  40. Gambichler T, Regeniter P, Bechara FG, Orlikov A, Vasa R, Moussa G, Stucker M, Altmeyer P, Hoffmann K (2007) Characterization of benign and malignant melanocytic skin lesions using optical coherence tomography in vivo. J Am Acad Dermatol 57(4):629–637. doi:10.1016/j.jaad.2007.05.029

    Article  PubMed  Google Scholar 

  41. Gladkova ND, Petrova GA, Nikulin NK, Radenska-Lopovok SG, Snopova LB, Chumakov YP, Nasonova VA, Gelikonov VM, Gelikonov GV, Kuranov RV, Sergeev AM, Feldchtein FI (2000) In vivo optical coherence tomography imaging of human skin: norm and pathology. Skin Res Technol 6(1):6–16

    Article  PubMed  Google Scholar 

  42. Glogau RG (2000) The risk of progression to invasive disease. J Am Acad Dermatol 42(1):23–24

    Article  PubMed  CAS  Google Scholar 

  43. Gotzinger E, Pircher M, Geitzenauer W, Ahlers C, Baumann B, Michels S, Schmidt-Erfurth U, Hitzenberger CK (2008) Retinal pigment epithelium segmentation by polarization sensitive optical coherence tomography. Opt Express 16(21):16410–16422

    Article  PubMed  Google Scholar 

  44. Graf RN, Robles F, Chen X, Wax A (2010) Detecting precancerous lesions in the hamster cheek pouch using spectroscopic white-light optical coherence tomography to assess nuclear morphology via spectral oscillations. J Biomed Opt 14(6):064030. doi:10.1117/1.3269680

    Google Scholar 

  45. Hamdoon Z, Jerjes W, Upile T, Hopper C (2011) Optical coherence tomography-guided photodynamic therapy for skin cancer: case study. Photodiagnosis Photodyn Ther 8(1):49–52. doi:10.1016/j.pdpdt.2010.08.004

    Article  PubMed  Google Scholar 

  46. Hendriks FM, Brokken D, Oomens CW, Baaijens FP (2004) Influence of hydration and experimental length scale on the mechanical response of human skin in vivo, using optical coherence tomography. Skin Res Technol 10(4):231–241. doi:10.1111/j.1600-0846.2004.00077.x

    Article  PubMed  CAS  Google Scholar 

  47. Holmes J, Hattersley S (2009) Image blending and speckle noise reduction in multi-beam OCT. Proc SPIE 7168(1):71681N. doi:10.1117/12.808575

    Article  Google Scholar 

  48. Huang D, Swanson EA, Lin CP, Schuman JS, Stinson WG, Chang W, Hee MR, Flotte T, Gregory K, Puliafito CA, Fujimoto JG et al (1991) Optical coherence tomography. Science 254(5035):1178–1181

    Article  PubMed  CAS  Google Scholar 

  49. Izatt JA, Kulkarni MD, Yazdanfar S, Barton JK, Welch AJ (1997) In vivo bidirectional color Doppler flow imaging of picoliter blood volumes using optical coherence tomography. Opt Lett 22(18):1439–1441

    Article  PubMed  CAS  Google Scholar 

  50. Jorgensen TM, Tycho A, Mogensen M, Bjerring P, Jemec GB (2008) Machine-learning classification of non-melanoma skin cancers from image features obtained by optical coherence tomography. Skin Res Technol 14(3):364–369. doi:10.1111/j.1600-0846.2008.00304.x

    Article  PubMed  Google Scholar 

  51. Josse G, George J, Black D (2011) Automatic measurement of epidermal thickness from optical coherence tomography images using a new algorithm. Skin Res Technol. doi:10.1111/j.1600-0846.2011.00499.x

  52. Kartakoullis A, Bousi E, Pitris C (2010) Scatterer size-based analysis of optical coherence tomography images using spectral estimation techniques. Opt Express 18(9):9181–9191. doi:10.1364/OE.18.009181

    Article  PubMed  Google Scholar 

  53. Kasseck C, Jaedicke V, Gerhardt NC, Welp H, Hofmann MR (2010) Substance identification by depth resolved spectroscopic pattern reconstruction in frequency domain optical coherence tomography. Opt Commun 283(23):4816–4822

    Google Scholar 

  54. Kennedy BF, Hillman TR, McLaughlin RA, Quirk BC, Sampson DD (2009) In vivo dynamic optical coherence elastography using a ring actuator. Opt Express 17(24):21762–21772. doi:10.1364/OE.17.021762

    Article  PubMed  CAS  Google Scholar 

  55. Khandwala M, Penmetsa BR, Dey S, Schofield JB, Jones CA (2010) Podoleanu a imaging of periocular basal cell carcinoma using en face optical coherence tomography: a pilot study. Br J Ophthalmol 94(10):1332–1336. doi:10.1136/bjo.2009.170811

    Article  PubMed  CAS  Google Scholar 

  56. Knuttel A, Boehlau-Godau M (2000) Spatially confined and temporally resolved refractive index and scattering evaluation in human skin performed with optical coherence tomography. J Biomed Opt 5(1):83–92. doi:10.1117/1.429972

    Article  PubMed  CAS  Google Scholar 

  57. Knuttel A, Bonev S, Knaak W (2004) New method for evaluation of in vivo scattering and refractive index properties obtained with optical coherence tomography. J Biomed Opt 9(2):265–273. doi:10.1117/1.1647544

    Article  PubMed  CAS  Google Scholar 

  58. Kodach VM, Faber DJ, van Marle J, van Leeuwen TG, Kalkman J (2011) Determination of the scattering anisotropy with optical coherence tomography. Opt Express 19(7):6131–6140

    Article  PubMed  CAS  Google Scholar 

  59. Konig K, Speicher M, Buckle R, Reckfort J, McKenzie G, Welzel J, Koehler MJ, Elsner P, Kaatz M (2009) Clinical optical coherence tomography combined with multiphoton tomography of patients with skin diseases. J Biophotonics 2(6–7):389–397. doi:10.1002/jbio.200910013

    Article  PubMed  Google Scholar 

  60. Korde VR, Bonnema GT, Xu W, Krishnamurthy C, Ranger-Moore J, Saboda K, Slayton LD, Salasche SJ, Warneke JA, Alberts DS, Barton JK (2007) Using optical coherence tomography to evaluate skin sun damage and precancer. Lasers Surg Med 39(9):687–695. doi:10.1002/lsm.20573

    Article  PubMed  Google Scholar 

  61. Lamirel C, Newman N, Biousse V (2009) The use of optical coherence tomography in neurology. Rev Neurol Dis 6(4):E105–E120

    PubMed  Google Scholar 

  62. Lankenau E, Welzel J, Birngruber R, Engelhardt R (1997) In Vivo Tissue Measurements with Optical low Coherence Tomography. In: Tuchin V, Podbielska H, Ovrin B (eds) Coherence domain optical methods in biomedical science and clinical applications. Proc Soc Photo-Opt Instrum Eng, SPIE. 2981:78–84

  63. Leitgeb R, Hitzenberger C, Fercher A (2003) Performance of fourier domain vs time domain optical coherence tomography. Opt Express 11(8):889–894

    Article  PubMed  CAS  Google Scholar 

  64. Leitgeb R, Schmetterer L, Drexler W, Fercher A, Zawadzki R, Bajraszewski T (2003) Real-time assessment of retinal blood flow with ultrafast acquisition by color Doppler Fourier domain optical coherence tomography. Opt Express 11(23):3116–3121

    Article  PubMed  Google Scholar 

  65. Leitgeb R, Wojtkowski M, Kowalczyk A, Hitzenberger CK, Sticker M, Fercher AF (2000) Spectral measurement of absorption by spectroscopic frequency-domain optical coherence tomography. Opt Lett 25(11):820–822

    Article  PubMed  CAS  Google Scholar 

  66. Liu Z, Guo Z, Zhuang Z, Zhai J, Xiong H, Zeng C (2010) Quantitative optical coherence tomography of skin lesions induced by different ultraviolet B sources. Phys Med Biol 55(20):6175–6185. doi:10.1088/0031-9155/55/20/009

    Article  PubMed  Google Scholar 

  67. Mogensen M, Joergensen TM, Nurnberg BM, Morsy HA, Thomsen JB, Thrane L, Jemec GB (2009) Assessment of optical coherence tomography imaging in the diagnosis of non-melanoma skin cancer and benign lesions versus normal skin: observer-blinded evaluation by dermatologists and pathologists. Dermatol Surg 35(6):965–972. doi:10.1111/j.1524-4725.2009.01164.x

    Article  PubMed  CAS  Google Scholar 

  68. Mogensen M, Morsy HA, Nurnberg BM, Jemec GB (2008) Optical coherence tomography imaging of bullous diseases. J Eur Acad Dermatol Venereol 22(12):1458–1464. doi:10.1111/j.1468-3083.2008.02917.x

    Article  PubMed  CAS  Google Scholar 

  69. Mogensen M, Morsy HA, Thrane L, Jemec GB (2008) Morphology and epidermal thickness of normal skin imaged by optical coherence tomography. Dermatology 217(1):14–20. doi:10.1159/000118508

    Article  PubMed  Google Scholar 

  70. Mogensen M, Nurnberg BM, Forman JL, Thomsen JB, Thrane L, Jemec GB (2009) In vivo thickness measurement of basal cell carcinoma and actinic keratosis with optical coherence tomography and 20-MHz ultrasound. Br J Dermatol 160(5):1026–1033. doi:10.1111/j.1365-2133.2008.09003.x

    Article  PubMed  CAS  Google Scholar 

  71. Mogensen M, Thrane L, Jorgensen TM, Andersen PE, Jemec GB (2009) OCT imaging of skin cancer and other dermatological diseases. J Biophotonics 2(6–7):442–451. doi:10.1002/jbio.200910020

    Article  PubMed  Google Scholar 

  72. Morgner U, Drexler W, Kartner FX, Li XD, Pitris C, Ippen EP, Fujimoto JG (2000) Spectroscopic optical coherence tomography. Opt Lett 25(2):111–113

    Article  PubMed  CAS  Google Scholar 

  73. Morsy H, Kamp S, Thrane L, Behrendt N, Saunder B, Zayan H, Elmagid EA, Jemec GB (2010) Optical coherence tomography imaging of psoriasis vulgaris: correlation with histology and disease severity. Arch Dermatol Res 302(2):105–111. doi:10.1007/s00403-009-1000-4

    Article  PubMed  Google Scholar 

  74. Neerken S, Lucassen GW, Bisschop MA, Lenderink E, Nuijs TA (2004) Characterization of age-related effects in human skin: a comparative study that applies confocal laser scanning microscopy and optical coherence tomography. J Biomed Opt 9(2):274–281. doi:10.1117/1.1645795

    Article  PubMed  Google Scholar 

  75. Nelson JS, Kelly KM, Zhao Y, Chen Z (2001) Imaging blood flow in human port-wine stain in situ and in real time using optical Doppler tomography. Arch Dermatol 137(6):741–744

    PubMed  CAS  Google Scholar 

  76. Olmedo JM, Warschaw KE, Schmitt JM, Swanson DL (2006) Optical coherence tomography for the characterization of basal cell carcinoma in vivo: a pilot study. J Am Acad Dermatol 55(3):408–412. doi:10.1016/j.jaad.2006.03.013

    Article  PubMed  Google Scholar 

  77. Pagnoni A, Knüttel A, Welker P, Rist M, Stoudemayer T, Kolbe L, Sadiq I, Kligman A (1999) Optical coherence tomography in dermatology. Skin Res Technol 5:83–87

    Article  Google Scholar 

  78. Patel JK, Konda S, Perez OA, Amini S, Elgart G, Berman B (2008) Newer technologies/techniques and tools in the diagnosis of melanoma. Eur J Dermatol 18(6):617–631. doi:10.1684/ejd.2008.0508

    PubMed  Google Scholar 

  79. Pierce MC, Strasswimmer J, Hyle Park B, Cense B, De Boer JF (2004) Birefringence measurements in human skin using polarization-sensitive optical coherence tomography. J Biomed Opt 9(2):287–291. doi:10.1117/1.1645797

    Article  PubMed  Google Scholar 

  80. Pircher M, Gotzinger E, Leitgeb R, Fercher A, Hitzenberger C (2003) Measurement and imaging of water concentration in human cornea with differential absorption optical coherence tomography. Opt Express 11(18):2190–2197

    Article  PubMed  CAS  Google Scholar 

  81. Robles F, Graf RN, Wax A (2009) Dual window method for processing spectroscopic optical coherence tomography signals with simultaneously high spectral and temporal resolution. Opt Express 17(8):6799–6812

    Article  PubMed  Google Scholar 

  82. Robles FE, Chowdhury S, Wax A (2010) Assessing hemoglobin concentration using spectroscopic optical coherence tomography for feasibility of tissue diagnostics. Opt Express 1(1):310–317

    CAS  Google Scholar 

  83. Sacchet D, Moreau J, Georges P, Dubois A (2008) Simultaneous dual-band ultra-high resolution full-field optical coherence tomography. Opt Express 16(24):19434–19446

    Article  PubMed  CAS  Google Scholar 

  84. Sainter AW, King TA, Dickinson MR (2004) Effect of target biological tissue and choice of light source on penetration depth and resolution in optical coherence tomography. J Biomed Opt 9(1):193–199. doi:10.1117/1.1628243

    Article  PubMed  Google Scholar 

  85. Sakai S, Nakagawa N, Yamanari M, Miyazawa A, Yasuno Y, Matsumoto M (2009) Relationship between dermal birefringence and the skin surface roughness of photoaged human skin. J Biomed Opt 14(4):044032. doi:10.1117/1.3207142

    Article  PubMed  Google Scholar 

  86. Salvini C, Massi D, Cappetti A, Stante M, Cappugi P, Fabbri P, Carli P (2008) Application of optical coherence tomography in non-invasive characterization of skin vascular lesions. Skin Res Technol 14(1):89–92. doi:10.1111/j.1600-0846.2007.00265.x

    PubMed  Google Scholar 

  87. Sand M, Gambichler T, Moussa G, Bechara FG, Sand D, Altmeyer P, Hoffmann K (2006) Evaluation of the epidermal refractive index measured by optical coherence tomography. Skin Res Technol 12(2):114–118. doi:10.1111/j.0909-752X.2006.00144.x

    Article  PubMed  CAS  Google Scholar 

  88. Sauermann K, Gambichler T, Wilmert M, Rotterdam S, Stucker M, Altmeyer P, Hoffmann K (2002) Investigation of basal cell carcinoma [correction of carcionoma] by confocal laser scanning microscopy in vivo. Skin Res Technol 8(3):141–147

    Article  PubMed  CAS  Google Scholar 

  89. Saxer CE, de Boer JF, Park BH, Zhao Y, Chen Z, Nelson JS (2000) High-speed fiber based polarization-sensitive optical coherence tomography of in vivo human skin. Opt Lett 25(18):1355–1357

    Article  PubMed  CAS  Google Scholar 

  90. Schmitt J (1998) OCT elastography: imaging microscopic deformation and strain of tissue. Opt Express 3(6):199–211

    Article  PubMed  CAS  Google Scholar 

  91. Schmitt JM (1999) Optical coherence tomography. IEEE J Sel Top Quantum Electr 5:1205–1215

    Article  CAS  Google Scholar 

  92. Schmitt JM (1999) Optical coherence tomography (OCT): a review. IEEE J Sel Top Quantum Electr 5(4):1205–1215

    Article  CAS  Google Scholar 

  93. Smith LE, Bonesi M, Smallwood R, Matcher SJ, Macneil S (2010) Using swept-source optical coherence tomography to monitor the formation of neo-epidermis in tissue-engineered skin. J Tissue Eng Regen Med. doi:10.1002/term.281

  94. Spoler F, Forst M, Marquardt Y, Hoeller D, Kurz H, Merk H, Abuzahra F (2006) High-resolution optical coherence tomography as a non-destructive monitoring tool for the engineering of skin equivalents. Skin Res Technol 12(4):261–267. doi:10.1111/j.0909-752X.2006.00163.x

    Article  PubMed  CAS  Google Scholar 

  95. Spoler F, Kray S, Grychtol P, Hermes B, Bornemann J, Forst M, Kurz H (2007) Simultaneous dual-band ultra-high resolution optical coherence tomography. Opt Express 15(17):10832–10841

    Article  PubMed  Google Scholar 

  96. Srinivas SM, de Boer JF, Park H, Keikhanzadeh K, Huang HE, Zhang J, Jung WQ, Chen Z, Nelson JS (2004) Determination of burn depth by polarization-sensitive optical coherence tomography. J Biomed Opt 9(1):207–212. doi:10.1117/1.1629680

    Article  PubMed  Google Scholar 

  97. Strasswimmer J, Pierce MC, Park BH, Neel V, de Boer JF (2004) Polarization-sensitive optical coherence tomography of invasive basal cell carcinoma. J Biomed Opt 9(2):292–298. doi:10.1117/1.1644118

    Article  PubMed  Google Scholar 

  98. Tang S, Krasieva TB, Chen Z, Tempea G, Tromberg BJ (2006) Effect of pulse duration on two-photon excited fluorescence and second harmonic generation in nonlinear optical microscopy. J Biomed Opt 11(2):020501. doi:10.1117/1.2177676

    Article  PubMed  Google Scholar 

  99. Tearney GJ, Brezinski ME, Bouma BE, Boppart SA, Pitris C, Southern JF, Fujimoto JG (1997) In vivo endoscopic optical biopsy with optical coherence tomography. Science 276(5321):2037–2039

    Article  PubMed  CAS  Google Scholar 

  100. Thomas MW, Grichnik JM, Izatt JA (2007) Three-dimensional images and vessel rendering using optical coherence tomography. Arch Dermatol 143(11):1468–1469. doi:10.1001/archderm.143.11.1468

    Article  PubMed  Google Scholar 

  101. Unterhuber A, Povazay B, Bizheva K, Hermann B, Sattmann H, Stingl A, Le T, Seefeld M, Menzel R, Preusser M, Budka H, Schubert C, Reitsamer H, Ahnelt PK, Morgan JE, Cowey A, Drexler W (2004) Advances in broad bandwidth light sources for ultrahigh resolution optical coherence tomography. Phys Med Biol 49(7):1235–1246

    Article  PubMed  CAS  Google Scholar 

  102. Vakoc B, Yun S, de Boer J, Tearney G, Bouma B (2005) Phase-resolved optical frequency domain imaging. Opt Express 13(14):5483–5493

    Article  PubMed  CAS  Google Scholar 

  103. Vargas G, Chan EK, Barton JK, Rylander HG 3rd, Welch AJ (1999) Use of an agent to reduce scattering in skin. Lasers Surg Med 24(2):133–141. doi:10.1002/(SICI)1096-9101

    Article  PubMed  CAS  Google Scholar 

  104. Vargas G, Readinger A, Dozier SS, Welch AJ (2003) Morphological changes in blood vessels produced by hyperosmotic agents and measured by optical coherence tomography. Photochem Photobiol 77(5):541–549

    Article  PubMed  CAS  Google Scholar 

  105. Vo-Dinh T (ed) (2003) Biomedical Photonics Handbook, 1 edn. SPIE, CRC Press, Boca Raton

  106. Wang L, Wang Y, Guo S, Zhang J, Bachman M (2004) Frequency domain phase-resolved optical Doppler and Doppler variance tomography optics communications 242(4–6):345–350

    CAS  Google Scholar 

  107. Wang Y, Zhao Y, Nelson JS, Chen Z, Windeler RS (2003) Ultrahigh-resolution optical coherence tomography by broadband continuum generation from a photonic crystal fiber. Opt Lett 28(3):182–184

    Article  PubMed  Google Scholar 

  108. Weissman J, Hancewicz T, Kaplan P (2004) Optical coherence tomography of skin for measurement of epidermal thickness by shapelet-based image analysis. Opt Express 12(23):5760–5769

    Article  PubMed  Google Scholar 

  109. Welzel J (2001) Optical coherence tomography in dermatology: a review. Skin Res Technol 7(1):1–9

    Article  PubMed  CAS  Google Scholar 

  110. Welzel J, Bruhns M, Wolff HH (2003) Optical coherence tomography in contact dermatitis and psoriasis. Arch Dermatol Res 295(2):50–55. doi:10.1007/s00403-003-0390-y

    Article  PubMed  Google Scholar 

  111. Welzel J, Lankenau E, Birngruber R, Engelhardt R (1997) Optical coherence tomography of the human skin. J Am Acad Dermatol 37(6):958–963, S0190-9622(97)70072-0 [pii]

    Article  PubMed  CAS  Google Scholar 

  112. Welzel J, Lankenau E, Birngruber R, Engelhardt R (1998) Optical coherence tomography of the skin. Curr Probl Dermatol 26:27–37

    Article  PubMed  CAS  Google Scholar 

  113. Welzel J, Lankenau E, Hüttmann G, Birngruber R (eds) (2008) OCT in dermatology. Handbook of optical coherence tomography. Springer, Berlin

    Google Scholar 

  114. Welzel J, Noack J, Lankenau E, Engelhardt R (2002) Optical coherence tomography in dermatology. Handbook of optical coherence tomography. Marcel Dekker, Inc., New York

    Google Scholar 

  115. Welzel J, Reinhardt C, Lankenau E, Winter C, Wolff HH (2004) Changes in function and morphology of normal human skin: evaluation using optical coherence tomography. Br J Dermatol 150(2):220–225

    Article  PubMed  CAS  Google Scholar 

  116. Wieser W, Biedermann BR, Klein T, Eigenwillig CM, Huber R (2010) Multi-megahertz OCT: high quality 3D imaging at 20 million A-scans and 4.5 GVoxels per second. Opt Express 18(14):14685–14704. doi:10.1364/OE.18.014685

    Article  PubMed  Google Scholar 

  117. Wilder-Smith P, Krasieva T, Jung WG, Zhang J, Chen Z, Osann K, Tromberg B (2005) Noninvasive imaging of oral premalignancy and malignancy. J Biomed Opt 10(5):051601. doi:10.1117/1.2098930

    Article  PubMed  Google Scholar 

  118. Xu C, Kamalabadi F, Boppart SA (2005) Comparative performance analysis of time-frequency distributions for spectroscopic optical coherence tomography. Appl Opt 44(10):1813–1822

    Article  PubMed  Google Scholar 

  119. Yang VXD, Pekar J, Lo SSW, Gordon ML, Wilson BC, Vitkina IA (2003) Optical coherence and Doppler tomography for monitoring tissue changes induced by laser thermal therapy—An in vivo feasibility study. Rev Sci Instrum 74(1):437–440

    Article  CAS  Google Scholar 

  120. Yeh AT, Kao B, Jung WG, Chen Z, Nelson JS, Tromberg BJ (2004) Imaging wound healing using optical coherence tomography and multiphoton microscopy in an in vitro skin-equivalent tissue model. J Biomed Opt 9(2):248–253. doi:10.1117/1.1648646

    Article  PubMed  Google Scholar 

  121. Zhang J, Chen Z (2005) In vivo blood flow imaging by a swept laser source based Fourier domain optical Doppler tomography. Opt Express 13(19):7449–7457

    Article  PubMed  Google Scholar 

  122. Zhao S, Gu Y, Xue P, Guo J, Shen T, Wang T, Huang N, Zhang L, Qiu H, Yu X, Wei X (2010) Imaging port wine stains by fiber optical coherence tomography. J Biomed Opt 15(3):036020. doi:10.1117/1.3445712

    Article  PubMed  Google Scholar 

  123. Zhao Y, Chen Z, Saxer C, Xiang S, de Boer JF, Nelson JS (2000) Phase-resolved optical coherence tomography and optical Doppler tomography for imaging blood flow in human skin with fast scanning speed and high velocity sensitivity. Opt Lett 25(2):114–116

    Article  PubMed  CAS  Google Scholar 

  124. Treu CM, Lupi O, Bottino DA, Bouskela E (2011) Sidestream dark field imaging: the evolution of real-time visualization of cutaneous microcirculation and its potential application in dermatology. Arch Dermatol Res 303:69–78

    Article  PubMed  Google Scholar 

Download references

Author information

Authors and Affiliations

Authors

Corresponding author

Correspondence to Thilo Gambichler.

Rights and permissions

Reprints and permissions

About this article

Cite this article

Gambichler, T., Jaedicke, V. & Terras, S. Optical coherence tomography in dermatology: technical and clinical aspects. Arch Dermatol Res 303, 457–473 (2011). https://doi.org/10.1007/s00403-011-1152-x

Download citation

  • Received:

  • Revised:

  • Accepted:

  • Published:

  • Issue Date:

  • DOI: https://doi.org/10.1007/s00403-011-1152-x

Keywords

Navigation