Table 1

Intraobserver reliability of the different clinical and ultrasonographic scoring systems evaluated twice with a 2–4 day interval in seven patients with active rheumatoid arthritis

Scoring systemICC (95% CI)Weighted κ (95% CI)
Joint count*
 20 Clinical0.60 (−0.08 to 0.90)0.56 (−0.07 to 1.00)
 20 US B mode0.85 (0.45 to 0.97)0.83 (0.62 to 1.00)
 20 US power Doppler0.96 (0.83 to 0.99)0.95 (0.91 to 1.00)
 28 Clinical0.82 (0.37 to 0.96)0.80 (0.63 to 0.97)
 28 US B mode0.97 (0.87 to 0.99)0.97 (0.92 to 1.00)
 28 US power Doppler0.72 (0.14 to 0.93)0.69 (0.60 to 0.79)
 38 Clinical0.81 (0.34 to 0.96)0.78 (0.63 to 0.93)
 38 US B mode0.90 (0.61 to 0.98)0.88 (0.75 to 1.00)
 38 US power Doppler0.85 (0.45 to 0.97)0.82 (0.73 to 0.92)
Joint score*
 20 Clinical0.53 (−0.18 to 0.88)0.48 (−0.11 to 1.00)
 20 US B mode0.87 (0.51 to 0.97)0.85 (0.68 to 1.00)
 20 US power Doppler0.91 (0.64 to 0.98)0.90 (0.78 to 1.00)
 28 Clinical0.82 (0.37 to 0.96)0.79 (0.52 to 1.00)
 28 US B mode0.92 (0.67 to 0.98)0.91 (0.82 to 0.99)
 28 US power Doppler0.61 (−0.06 to 0.90)0.58 (0.43 to 0.74)
 38 Clinical0.63 (−0.03 to 0.91)0.59 (0.21 to 0.98)
 38 US B mode0.92 (0.67 to 0.98)0.91 (0.77 to 1.00)
 38 US power Doppler0.73 (0.16 to 0.94)0.71 (0.50 to 0.91)
  • * See Patients and methods section for the definition of count versus score and for the description of the evaluated joints.

  • ICC, intraclass correlation coefficient; US, ultrasound.