Table 3

 Concordance and discordance between the two MRI techniques for each reader and for each reading. Evaluation was performed by comparing the same VUs of each patient by both MRI techniques for inflammation, as assessed by the ASspiMRI-a

Concordant VU pairs (%)Discordant VU pairs (%)
Reader 1
    Reading 180.119.9
    Reading 284.515.5
Reader 2
    Reading 181.118.9
    Reading 289.011.0