RT Journal Article SR Electronic T1 LB0002 Biomechanical therapy for osteoarthritis of the knee: a randomised controlled trial (BIOTOK) JF Annals of the Rheumatic Diseases JO Ann Rheum Dis FD BMJ Publishing Group Ltd and European League Against Rheumatism SP 82 OP 83 DO 10.1136/annrheumdis-2018-eular.7892 VO 77 IS Suppl 2 A1 S. Reichenbach A1 S. Heldner A1 A. Lenz A1 D. Felson A1 P. Jüni YR 2018 UL http://ard.bmj.com/content/77/Suppl_2/82.abstract AB Background Biomechanics plays an important role in knee osteoarthritis (OA). A new biomechanical footwear system aims at altering knee loading patterns and retraining neuromuscular control of the lower extremities. It consists of shoes with two adjustable convex pods at the soles, which are adjusted based on gait analysis, with the hypothesis that adjustments of the location of the pods will alter limb biomechanics so as to unload diseased compartments of the knee and that walking on the convex pods will facilitate muscular retraining.Objectives The aim of this trial was to compare the efficacy and safety of the new biomechanical footwear with an identical appearing shoe with flat pods (the sham device) in relieving pain and improving physical function in patients with knee OA.Methods In this randomised sham-controlled trial, patients with radiological knee OA (Kellgren-Lawrence grade ≥2), knee pain lasting for ≥6 months, and moderate pain on the WOMAC pain subscale (≥3 on a standardised scale from 0 to 10) were randomly assigned 1:1 to the biomechanical footwear or the sham device. The same shoe or device was provided for bilateral use. Patients in both groups were instructed to use the footwear for 30 minutes/day during the first week, and to increase use by 10 minutes/day each week to a maximum of 5 hours/day at 24 weeks. After 4, 8, 12, and 16 weeks, each patient’s footwear was re-calibrated by technicians. Because the sham device had no adjustable pods on the soles, technicians pretended to make appropriate changes.The primary endpoint was knee pain at the end of treatment in the knee with more pain at screening, assessed with the WOMAC pain subscale. Secondary outcomes were WOMAC physical function and stiffness subscales. All subscales were standardised to range from 0 to 10. These outcomes were analysed using linear models adjusted for baseline values and the two stratification factors uni- vs. bilateral, and medial vs. lateral osteoarthritis at randomization, using multiple imputation.Results Of 697 patients assessed for eligibility, 220 were randomised: 111 to the experimental footwear and 109 to the sham device. The mean age was 65.2 years (SD 9.2) and the mean body mass index was 28.0 (SD 4.6). Overall, 47.3% were women and 88.2% had medial knee OA in the index knee. The mean WOMAC pain score at baseline was 4.1 (SD 1.9). Seven patients in the experimental group and 13 in the sham group dropped out. At the end of the trial, the adjusted mean difference for WOMAC pain was 1.34 (95% CI: 0.92 to 1.77) in favour of the experimental footwear. The adjusted mean difference was 1.42 (0.93 to 1.91) for WOMAC stiffness and 1.12 (0.73 to 1.50) for WOMAC physical function (figure 1). Three serious adverse events occurred in the experimental group, compared with 9 in the sham group; none were treatment-related. Thirty adverse events occurred in the experimental group, compared with 36 in the sham group; 18 and 17 of these, respectively, were possibly treatment-related.Conclusions This trial suggests that the new biomechanical footwear system is both efficacious and safe in relieving knee pain in patients with knee OA.Disclosure of Interest S. Reichenbach Grant/research support from: Mäxi Foundation, S. Heldner: None declared, A. Lenz: None declared, D. Felson: None declared, P. Jüni: None declared