TY - JOUR T1 - Screening for interstitial lung disease in systemic sclerosis: performance of high-resolution CT with limited number of slices: a prospective study JF - Annals of the Rheumatic Diseases JO - Ann Rheum Dis SP - 2069 LP - 2073 DO - 10.1136/annrheumdis-2014-205637 VL - 73 IS - 12 AU - Thomas Frauenfelder AU - Anna Winklehner AU - Thi Dan Linh Nguyen AU - Rucsandra Dobrota AU - Stephan Baumueller AU - Britta Maurer AU - Oliver Distler Y1 - 2014/12/01 UR - http://ard.bmj.com/content/73/12/2069.abstract N2 - Objectives Early diagnosis of interstitial lung disease (ILD), currently the main cause of death in systemic sclerosis (SSc), is needed. The gold standard is high-resolution CT (HRCT) of the chest, but regular screening faces the risk of increased radiation exposure. We performed a prospective validation of a dedicated, 9-slice HRCT protocol with reduced radiation dose for the detection of ILD in patients with SSc. Methods We analysed 170/205 consecutive patients with SSc. Whole-chest HRCT, serving as standard of reference, and the reduced HRCT with nine slices allocated according to a basal–apical gradient were obtained. ILD presence, extent (> or <20%) and diagnostic confidence were assessed. The reduced HRCT was independently analysed by two blinded radiologists, who also evaluated image quality. Radiation dose parameters were calculated. Results Standard chest HRCT showed ILD in 77/170 patients. With the reduced HRCT, 68/77 cases with ILD were identified (sensitivity 88.3%, both readers). The accuracy (91.8%, reader 1; 94.7%, reader 2), diagnostic confidence (98.8%, reader 1; 95.3%, reader 2) and image quality rates were high. Minimal ILD was correctly quantified in 73.1% (reader 1)/71.2% (reader 2) and extensive ILD in 88% (reader 1)/100% (reader 2). Importantly, the reduced HRCT had a significantly lower radiation dose. The mean dose length product (effective dose) was only 5.66±4.46 mGycm (0.08±0.06 mSv) compared with the standard protocol dose of 149.00±95.90 mGycm (2.09±1.34 mSv). Conclusions The above-described reduced chest HRCT protocol reliably detects even mild SSc-ILD in clinical practice, with the advantage of a much lower radiation dose compared with standard whole-chest HRCT. ER -