Table 3

 Comparison of test results using kits from different manufacturers

Author (date)Patients with RA/controlsTest for anti-CCP2Sensitivity (%)Specificity (%)
ED, Euro-Diagnostica; AS, Axis-Shield.
Dubucquoi (2004)3346/22ED8591
AS8291
INOVA8595.5
Garcia-Berrocal (2005)2287/46ED7485
AS4385
INOVA7785
Fernandez-Suarez (2005)1253/75ED52.8100
AS52.8100
INOVA58.5100
Greiner (2005)1687/246ED8198
INOVA8097
EUROIMMUN8198