Annals of the Rheumatic Diseases 2006;65:1613-1619
EXTENDED REPORT
Reproducibility and inter-reader agreement of a scoring system for ultrasound evaluation of hip osteoarthritis
The Parker Institute, Frederiksberg Hospital, Copenhagen, Denmark
Correspondence to:
Professor H Bliddal
The Parker Institute, Frederiksberg Hospital, DK 2000 Copenhagen F, Denmark;hb{at}fh.hosp.dk
Objective: To evaluate the intra-reader and inter-reader agreements of ultrasonographic assessments of hip joints in patients with hip osteoarthritis.
Design: Ultrasonography was performed on 100 patients with hip osteoarthritis at 14 MHz using a 815 MHz linear probe. Dynamic sweeps of the hip and representative still images were used for the analysis. A semiquantitative grading score was introduced in the evaluation of the ultrasound pictures and compared with an overall ultrasound evaluation. The evaluation was performed by a specialist in ultrasonography and a rheumatologist trained in musculoskeletal ultrasound examination. Clinical pain assessment and joint aspiration were obtained in parallel with the ultrasonography.
Results: Intraobserver agreement represented by intraclass correlation coefficients (ICC) (exact agreement in percentage; unweighted
values) showed good to excellent correlation, 0.8 with regard to the osteophyte score, 0.78 with regard to the femoral head score, 0.71 with regard to the fluid score and 0.69 with regard to the synovial profile score. Interobserver agreement was fair to good with corresponding ICC 0.65, 0.63, 0.45 and 0.6, respectively. In comparison, the ICC for the global osteoarthritis and synovial assessments were 0.7 and 0.72, respectively, for the intraobserver rating and 0.56 and 0.58, respectively, for the interobserver rating.
Conclusions: This study suggests that ultrasound is a reproducible method for the assessment of changes in the osseous surface and synovium-related inflammation. The semiquantitative scoring system presented seemed to match the global assessment of a trained ultrasound investigator and might be used by less-trained investigators.
Abbreviations: CCD, collumcapsule distance; ICC, intraclass correlation coefficient; VAS, Visual Analogue Scale
![]()
CiteULike
Complore
Connotea
Del.icio.us
Digg
Reddit
Technorati What's this?
This article has been cited by other articles:
-
Keen, H I, Wakefield, R J, Conaghan, P G
(2009). A systematic review of ultrasonography in osteoarthritis. Ann Rheum Dis
68: 611-619
[Abstract] [Full Text] -
Bruyn, G A W, Naredo, E, Moller, I, Moragues, C, Garrido, J, de Bock, G H, d'Agostino, M-A, Filippucci, E, Iagnocco, A, Backhaus, M, Swen, W A A, Balint, P, Pineda, C, Milutinovic, S, Kane, D, Kaeley, G, Narvaez, F J, Wakefield, R J, Narvaez, J A, de Augustin, J, Schmidt, W A
(2009). Reliability of ultrasonography in detecting shoulder disease in patients with rheumatoid arthritis. Ann Rheum Dis
68: 357-361
[Abstract] [Full Text] -
Atchia, I., Birrell, F., Kane, D.
(2007). A modular, flexible training strategy to achieve competence in diagnostic and interventional musculoskeletal ultrasound in patients with hip osteoarthritis. Rheumatology (Oxford)
46: 1583-1586
[Abstract] [Full Text]
Register for free content
The full back archive is now available for all BMJ Journals. Institutional subscribers may access the entire archive as part of their subscription. Personal subscribers will also have access to all content when logged in. Non-subscribers who register have free access to all articles published before 2006 right back to volume 1 issue 1. Register here to access the free archive of all BMJ Journals.
Don't forget to sign up for content alerts so you keep up to date with all the articles as they are published.